Thông số kỹ thuật:
Chức năng : True RMS, MEAN
DC V : 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V
AC V : [RMS] 50.000/500.00mV/5.0000/50.000/500.00/1000.0V
AC V : [MEAN] 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V
DCV+ACV : 5.0000/50.000/500.00/1000.0V
DC A : 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
AC A[RMS] :500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
AC A [MEAN] : 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A
DCA+ACA : 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A
Ω : 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ
Continuity buzzer : 500.0Ω
Diode test : 2.4V
C: 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF
F: 2.000~9.999/9.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz
Nhiệt độ : -200~1372ºC (K-type )
Chức năng khác : Data Hold (D/H), Auto Hold (A/H), Peak Hold * (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight
Nguồn : R6P (1.5V)×4
Kích thước : 192(L)×90(W)×49(D) mm
Cân nặng : 560g
Nguồn : LR44 (1.5V) × 2
Kích thước :192(L)×90(W)×49(D) mm
Khối lượng : 560g
Phụ kiện : Vỏ, Pin, HDSD
Bảo hành : 12 tháng
Hãng sản xuất : Kyoritsu – Nhật
Xuất xứ : Nhật
|
![]() (Photo: 1062) |
|||||||||||||||||||||||||
| Safety design for industrial use | ||
| • | Complies with IEC 61010-1 CAT.III 1000V, CAT.IV 600V | |
| • | Terminal shutter to prevent incorrect test leads’ insertion in current terminals | |
| • | Very wide operating temperature range from -20 to 55ºC | |
| Reliable support for data management | ||
| • | Large data internal memory | |
| KEW 1062: 10,000 data (logging), 100 data (manual) | ||
| KEW 1061: 1,000 data (logging), 100 data (manual) | ||
| • | Download data and Live Monitoring on a PC via the USB interface (Option for USB Communication set) |
|
| KEW 1061 | KEW 1062 | |||||||||||
| Detection mode | RMS | MEAN/RMS (switch) | ||||||||||
| DC V | 50.000/500.00/2400.0mV/5.0000/50.000/500.00/1000.0V (Input impedance: Approx. 100MΩ [50/500/2400mV], 10MΩ [5/50/500/1000V]) |±0.02%rdg±2dgt (Basic accuracy) |
|||||||||||
| AC V [RMS] |
50.000/500.00mV/5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V]) |
|||||||||||
| |±0.7%rdg±30dgt (Basic accuracy) | |±0.4%rdg±30dgt (Basic accuracy) | |||||||||||
| AC V [MEAN] * |
— | 50.000/500.00mV/ 5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [50/500mV/5V], 10MΩ<50pF [50/500/1000V]) |±1%rdg±30dgt (Basic accuracy) |
||||||||||
| DCV+ACV | 5.0000/50.000/500.00/1000.0V (Input impedance: 11MΩ<50pF [5V], 10MΩ<50pF [50/500/1000V]) |
|||||||||||
| |±1%rdg±10dgt (Basic accuracy) | |±0.5%rdg±10dgt (Basic accuracy) | |||||||||||
| DC A | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A |±0.2%rdg±5dgt (Basic accuracy) |
|||||||||||
| AC A [RMS] |
500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A | |||||||||||
| |±1%rdg±20dgt (Basic accuracy) | |±0.75%rdg±20dgt |(Basic accuracy) |
|||||||||||
| AC A [MEAN] * |
— | 500.00/5000.0µA/50.000/500.00mA/ 5.0000/10.000A |±1.5%rdg±20dgt (Basic accuracy) |
||||||||||
| DCA+ACA | 500.00/5000.0µA/50.000/500.00mA/5.0000/10.000A | |||||||||||
| |±1.5%rdg±10dgt (Basic accuracy) | |±1%rdg±10dgt (Basic accuracy) | |||||||||||
| Ω | 500.00Ω/5.0000/50.000/500.00kΩ/5.0000/50.000MΩ | |||||||||||
| |±0.1%rdg±2dgt (Basic accuracy) | |±0.05%rdg±2dgt (Basic accuracy) | |||||||||||
| LowPower-Ω * | — | 5.000/50.00/500.0kΩ/5.000MΩ |±0.2%rdg±3dgt (Basic accuracy) |
||||||||||
| Continuity buzzer | 500.0Ω (The buzzer turns on for resistances lower than 100±50Ω) | |||||||||||
| Diode test | 2.4000V Open curcuit voltage: <5V (Approx. 0.5mA Measuring Current) |
|||||||||||
| Capacitance | 5.000/50.00/500.0nF/5.000/50.00/500.0µF/5.000/50.00mF |±1%rdg±5dgt (Basic accuracy) |
|||||||||||
| Frequency | 2.000~9.999/9.00~99.99/90.0~999.9Hz/0.900~9.999/9.00~99.99kHz |±0.02%rdg±1dgt (Basic accuracy) |
|||||||||||
| DUTY | 10~90% |
|||||||||||
| Temperature | -200~1372ºC -328~2501.6ºF (with the use of K-type Temperature probe) |
|||||||||||
| Measurement functions |
DC Voltage, AC Voltage, DC Current, AC Current, Resistance, Frequency, Temperature, Capacitor, Duty cycle ratio, Decibel (dBV, dBm), Continuity Check, Diode Test, LowPower-Ω * | |||||||||||
| Other functions | Data Hold (D/H), Auto Hold (A/H), Peak Hold * (P/H), Range Hold (R/H), Maximum value (MAX), Minimum value (MIN), Average value (AVG), Zero Adjustment (Capacitor, Resistance), Relative values, Save to Memory, LCD backlight | |||||||||||
| Withstand voltage | 6,880V/5 sec. | |||||||||||
| Applicable standards |
IEC 61010-1 CAT.IV 600V, CAT.III 1000V Pollution degree 2, IEC 61010-031, IEC 61326-1 (EMC) |
|||||||||||
| Power source | R6P (1.5V)×4 (Auto power off: approx. 20 minutes) | |||||||||||
| Dimensions | 192(L)×90(W)×49(D) mm | |||||||||||
| Weight | Approx. 560g (including batteries) | |||||||||||
| Accessories | 7220A (Test leads), R6P×4, Instruction manual, 8926 (Fuse [440mA/1000V])×1 (included) 8927 (Fuse [10A/1000V])×1 (included) |
|||||||||||
![]()
| Option | |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||