Specifications:

Ranges

100 kHz … 150 MHz (76 MHz … 110 MHz, FM-Stereo)

Resolution

100 Hz (to 34,999 MHz); 1 kHz (above 35 MHz)

Accuracy

± 5 x 10-6 (5 ppm)

Range

-20 dBµV … 126 dBµV with open load / -133 dBm … +13 dBm on 50Ω

Resolution

1 dB, 0,1 dB

Accuracy

± 1 dB at 100 dBµV

Output impedance

50 Ω

Int. Modulation

400 Hz and 1 kHz

ext. Modulation

input impedance: 10 kΩ; input voltage: 3 Vpp ± 2%

Range (FM)

100 kHz at 1 … 150 MHz, carrier frequency x 10 % below 1 MHz

Accuracy (FM)

± 10 % of max. frequency deviation

Distortion(FM)

< 0,06 % at 10,7 MHz, 76 ... 110 MHz; < 0,11 % (at other ranges); at 75 kHz deviation and 1 kHz AF signal

Range (AM)

0 … 60 %

Resolution (AM)

0,1%

Accuracy (AM)

± 5% (100 kHz … 110 MHz)
± 5% (100 kHz … 110 MHz)
± 10% (110 kHz … 150 MHz)

Distortion (AM)

400 kHz … 30 MHz: < 0,65 % at 30 % Modulation, 1 kHz AV signal; other ranges: < 1,5 %

Separation

400 Hz … 1 kHz: 50 dB or better
400 Hz … 1 kHz: 50 dB or better
100 Hz … 10 kHz: 35 dB oder better
50 Hz … 15 kHz: 30 dB or better

Pilot signal

19 kHz ± 2 Hz

Distortion

< 0,07 % at 90 % Modulation

Preset keys

FM-Modulation: 3,5; 22,5; 75 kHz
FM-Modulation: 3,5; 22,5; 75 kHz
AM-Modulation: 30 %
Stereo-Modulation: 30 % and 100 %

Operation voltage

100 ~ 120 V / 200 ~ 240 V AC; 50/60 Hz switchable ext.

Dimension (WxHxD)

430 x 115 x 310 mm

Weight

7 kg

EAN-13

4250569400131

FM-AM Signal Generator, 100 kHz – 150 MHz

This unit is a high accuracy micro-processor controlled RF signal generator covering frequency range of 100 kHz … 150 MHz. In addition to an excellent AM/FM modulation capability, the output level can vary from -20 dBµV to 126 dBµV in 1 dB steps. This signal generator is designed specifically to test AM/FM radio, wireless phones under product development and production environment.

  • Carrier frequency range from 100 kHz … 150 MHz including FM-Stereo from 76 MHz to 110 MHz
  • Memory for presetting up to 100 settings
  • Frequency input up to 7 digits
  • GPIB interface serial
  • Fixed 30% AM modulation pushbutton switch
  • 3,5 and 22,5 kHz modulation pushbutton switches with 75 kHz deviation
  • 30% and 100% stereo modulation provisions
  • Backup battery against data loss
  • Safety: EN 61010-1; CAT II
  • Accessories: BNC RF-cable, power cable, spare fuse, operation manual

 

Ranges

100 kHz … 150 MHz (76 MHz … 110 MHz, FM-Stereo)

Resolution

100 Hz (to 34,999 MHz); 1 kHz (above 35 MHz)

Accuracy

± 5 x 10-6 (5 ppm)

Range

-20 dBµV … 126 dBµV with open load / -133 dBm … +13 dBm on 50Ω

Resolution

1 dB, 0,1 dB

Accuracy

± 1 dB at 100 dBµV

Output impedance

50 Ω

Int. Modulation

400 Hz and 1 kHz

ext. Modulation

input impedance: 10 kΩ; input voltage: 3 Vpp ± 2%

Range (FM)

100 kHz at 1 … 150 MHz, carrier frequency x 10 % below 1 MHz

Accuracy (FM)

± 10 % of max. frequency deviation

Distortion(FM)

< 0,06 % at 10,7 MHz, 76 ... 110 MHz; < 0,11 % (at other ranges); at 75 kHz deviation and 1 kHz AF signal

Range (AM)

0 … 60 %

Resolution (AM)

0,1%

Accuracy (AM)

± 5% (100 kHz … 110 MHz)
± 5% (100 kHz … 110 MHz)
± 10% (110 kHz … 150 MHz)

Distortion (AM)

400 kHz … 30 MHz: < 0,65 % at 30 % Modulation, 1 kHz AV signal; other ranges: < 1,5 %

Separation

400 Hz … 1 kHz: 50 dB or better
400 Hz … 1 kHz: 50 dB or better
100 Hz … 10 kHz: 35 dB oder better
50 Hz … 15 kHz: 30 dB or better

Pilot signal

19 kHz ± 2 Hz

Distortion

< 0,07 % at 90 % Modulation

Preset keys

FM-Modulation: 3,5; 22,5; 75 kHz
FM-Modulation: 3,5; 22,5; 75 kHz
AM-Modulation: 30 %
Stereo-Modulation: 30 % and 100 %

Operation voltage

100 ~ 120 V / 200 ~ 240 V AC; 50/60 Hz switchable ext.

Dimension (WxHxD)

430 x 115 x 310 mm

Weight

7 kg